OlympIQ
Read before you practise · 8 min

Titration Stoichiometry, Back-Titration and Accuracy vs Precision

Quantitative analysis problems all reduce to the same core move: convert a measured volume and concentration into moles, then track those moles through whatever stoichiometry the problem describes. Alongside that, knowing the difference between accuracy and precision lets you read a data set correctly.

NSEC · Analytical Chemistry · 3 linked questions · 100% coverage
Know this first

EDTA Titration Stoichiometry for a Calcium Carbonate Tablet is the central idea in this question pattern. Identify the condition in the stem before applying the method below.

Study deeper: NCERT Chemistry · Analytical Chemistry

Working an EDTA titration back to the original tablet composition

EDTA forms a 1:1 complex with Ca²⁺, so a straightforward titration problem is pure mole-tracking: find the moles of CaCO₃ in the original sample from its mass and molar mass, convert to a molarity for the prepared solution, scale down to the moles present in the titrated aliquot, then divide by the EDTA concentration to get the burette volume needed.

For a 1250 mg CaCO₃ tablet dissolved to 1.0 L: moles
CaCO₃ = 1.25 g / 100 g/mol = 0.0125 mol, giving a 0.0125 M solution

A 10.0 mL aliquot then contains 0.0125 M x 0.010 L = 1.25 x 10⁻⁴ mol Ca²⁺, which needs 1.25 x 10⁻⁴ mol / 0.0198 M = 6.31 mL of EDTA (using the 1:1 stoichiometry). Work every step in moles, and only convert to volume or mass at the very last step you actually need it.

Back-titration: using excess reagent, then measuring what is left over

When a sample cannot be titrated directly (for example, because it also contains an inert or hard-to-react impurity), back-titration adds a known EXCESS of one reagent to react with the sample completely, then titrates whatever excess remains with a second reagent to find out how much was actually used up by the sample. For a sample of MCl₂ contaminated with M(OH)₂ dissolved in a known excess of HCl: total moles HCl added minus moles HCl neutralised by the second titrant (NaOH) gives the moles of HCl that reacted with the sample itself. Since MCl₂ does not react with HCl at all (it is already a neutral salt), only the M(OH)₂ impurity consumes HCl, in a 1:2 ratio (M(OH)₂ + 2HCl → MCl₂ + 2H₂O). Divide the HCl consumed by 2 to get moles of M(OH)₂, convert to mass using the given molar mass, and divide by the total sample mass to get the percentage impurity.

Accuracy is closeness to the true value; precision is closeness among repeated measurements

Accuracy describes how close a set of measurements sits to the TRUE (expected) value; precision describes how close the measurements sit to EACH OTHER, regardless of whether that cluster is anywhere near the true value. A data set can be accurate on average (its mean is close to the true value) while still being imprecise (the individual readings are scattered widely around that average) — this is exactly what good-accuracy-poor-precision looks like: readings that average out close to the expected value, but that individually vary more than a tightly clustered, well-controlled titration should. Do not confuse this with a tightly clustered set that is centred on the WRONG value (that is good precision, poor accuracy instead), or a set that is both scattered AND off-centre (poor accuracy and poor precision together).

OlympIQ exam lens

  • ✓Work titration problems in moles throughout; convert to mass or volume only at the final step
  • ✓EDTA complexes Ca²⁺ in a 1:1 ratio — moles EDTA used equals moles Ca²⁺ present in the titrated aliquot
  • ✓Back-titration: (total moles of the excess reagent) minus (moles neutralised by the second titrant) equals moles that reacted with the sample itself
  • ✓In a back-titration, only the reactive impurity consumes the excess reagent — an inert component (like MCl₂ with HCl) does not
  • ✓Accuracy = closeness to the true value; precision = closeness among repeated measurements — a data set can have one without the other
OlympIQ trap

Do not assume a tightly clustered set of titration readings is automatically the accurate one. Tight clustering only shows good PRECISION — check separately whether that cluster is actually centred near the true, expected value before calling it accurate too.

Ready to try the pattern?

100% coverage across the 3 linked questions.

Practise 3 linked questions
Sign in to practise — your XP, streak and analysis update as you solve.